View Full Version : Water/Meth injector check valve, shutoff solenoid, tank location, etc
So I thought I was sold on a meth injection kit but then after further reading I see other kits and optional components. So the AEM injector has a built in check valve in the injector "to prevent unintended flow." The snow performance injectors don't have this but they offer a shutoff solenoid and "is used when mounting the injection nozzle lower than the reservoir or the reservoir is rear-mounted to prevent gravity flowing."
Has anyone had any experience with the concern of unintended flow? Why would tank location front/rear matter?
BaadVR4
09-04-2012, 04:29 PM
The concern is flow from the tank into the intake by gravity: as in the pump isn't running.
This is potentially possible if the tank is higher than the nozzle. That could occur two ways: 1. the tank is mounted physically higher than the nozzle. This is unlikely, but possible. Envision the Meth tank mounted in the stock battery location. Or 2. the tank is mounted in the trunk area and the car is parked/operated on a steep incline. with the rear higher than the front. Envision living in San Francisco.
In either of these two examples, the level of the Meth in the tank could be higher than the injector nozzle, establishing all the conditions for a siphon system and unintended flow of Meth from the tank to the intake without the pump running.
The check valves require a small pressure to open them to initiate flow. The solenoid valves stay closed until power is applied, usually done by hooking the solenoid power supply to the pump power supply.
Hope this helps.
Thanks, figured it was fairly simple but wanted to be sure I understood everything before ordering.