PDA

View Full Version : Datalogger MUT Initialization



reses
03-22-2014, 04:39 PM
I'm trying to datalog my 94 Hybrid car, I can do it with Mitsulogger and EvoScan but I would like to use something on my own, I searched about Serial port/OBD and some implementations but I'm still lost LOL, I have a FTDI chipset cable, this is the info that I got from "google".




Okay the Mut Protocol Init is alot like the ISO9141-2 Init.

We will be using 1 of the Pins from the OBD-II Connector for communicating.

Pin7 K line

If you take a Pin HIGH this means you are applying 12Volts to it.
If you take the Pin LOW you are applying 0V

The first thing that you need to do is to initialise the ECU so it knows you want to communicate.

This is done with the following routine:

'Slow Init
Take K Line High
Pause 300ms

'Send 0x01 (00000001) at rate of 5 baud (LSB) with a Start Bit and a Stop bit

'Send Startbit
Set K line low (0)
Pause 200ms

'Now to send out 0x01
'Send out bit0
Set K line high (1)
pause 200ms
'Send out bit1
Set K line low (0)
pause 200ms
'Send out bit2
Set K line low (0)
pause 200ms
'Send out bit3
Set K line low (0)
pause 200ms
'Send out bit4
Set K line low (0)
pause 200ms
'Send out bit5
Set K line low (0)
pause 200ms
'Send out bit6
Set K line low (0)
pause 200ms
'Send out bit7
Set K line low (0)
pause 200ms

'Send Stopbit
Set K line high (1)
Pause 200ms

Switch to 15625 baud

Receive C0 55 EF 85
send FE
Receive E4 ' First Byte of ECU ID
Send FF
Receive B3 ' Second byte of ECU ID
Send FE
Receive E4 ' First Byte of ECU ID
Send FF
Receive B3 ' Second Byte of ECU ID
Send FD
Receive 20
Send FD
Receive 20
Send FD
Receive 20

The ECU is now initialised and you can start sending requests depending on the info you want back.

For example if you wanted to know the RPM of the engine.

Send 21 and it will reply with a answer, then simply do a calculation on that result to get the true answer.

The calculation for RPM is 31.25*x

Will sort out a list of know Request ID's and their calculations next.

Followup post:

I have now been informed that after you do the 5 baud Init and then change Baud rate to Receive C0 55 EF 85, you can start sending request bytes straight away.


This is from the a guy from UK ( http://www.myrollingroad.com is offline).


I checked Mitsulogger inits but that doesnt look like the init described here.

Main code (I removed irrelevant lines):




FT_SetBaudRate(15625)
FT_SetDataCharacteristics(D2XX_Unit_NET.FT_Handle, (byte) 8, (byte) 0, (byte) 0)
FT_SetFlowControl(D2XX_Unit_NET.FT_Handle, 0, (byte) 0, (byte) 0)
FT_SetFlowControl(D2XX_Unit_NET.FT_Handle, 0, (byte) 0, (byte) 0);
FT_SetTimeouts(D2XX_Unit_NET.FT_Handle, 500, 500);
FT_Status = D2XX_Unit_NET.FT_SetLatencyTimer(D2XX_Unit_NET.FT_ Handle, (byte) 1);
SendByte("17"); send that hex string
Data = GetResponse(2); get 2 bytes response

n = 0;
while( n < 5)
{


FT_SetBreakOn(); break conditions
Sleep(1800); wait 1800ms;
FT_SetBreakOff();


GetResponse(4); get the 4 bytes from the ecu, ecuid??

sleep(150);

if(Data.Length >=4)
{
break; we got the init...
}
}

if(Data.Length <4)
{
timeout after 5 inits
}


Getresponse just checks the queue and return a string

recbytes, sentbytes; this is for status/display?

GetResponse(n)
{
status = FT_GetQueueStatus(ref recbytes);
string str;
if(status != 0) error...
str = "";
string buffer = new string with n+ spaces...

FT_Read_String(buffer,n,bytes); read available bytes


str = buffer;
return str;
}


send byte converts the hex string to an int and send that bytes to the device...





Any info on how to tackle this, obviously I tried that code/init on a c# sample but I didn't got the 4 bytes response, evoscan/mitsulogger get that right... I haven't tried any serial communications before, but I got some ftdi samples, I can do some things in c/c++/c#/java/python and almost any mid-high level programming language

Memphetic
03-26-2014, 02:26 AM
The code you posted... is that from mitsulogger, or your attempt at what you found?

reses
04-02-2014, 09:39 PM
Thats the init part of mitsulogger, there is no more development on mitsulogger or the mutlogger (that dev was on the open ecu forum), the ecu forum is dead by now.. right now I'm learning some android lol.. havent touched the init/communication with the ftdi library, I read on the ecu forum that you need to use the bit bang mode on the ftdi chipset (evoscan dev said that..).

reses
04-12-2014, 04:29 PM
Ok so I just found some info about the MUT init, is just a 5 baud byte (writes/breaks for turning the RTS line high/low after 200ms delay) with a start and stop bit, but I cant get the ECU to initialize, I'm using the FTDI Java driver with android and still NADA, any chance on a sample, Memphetic, you started a port of mmcd right?

EDIT: Got it, its kinda buggy but I managed to get the light blinking and got the ECU response.

6634