View Full Version : Stuck o2 sensor
FluffyCow
08-27-2013, 07:31 PM
My o2 was stuck(front). Removed o2 housing and pre cat. Found why my sensor was not reading. Anyway, how do I get a stuck o2 out?
Sent from my SAMSUNG-SGH-I747 using Tapatalk 4
Chris@Rvengeperformance
08-28-2013, 09:25 AM
Cut the wire off and use a 6 point socket. Heat the housing with map gas or acetylene if you have it.
Sent from my RM-845_nam_vzw_100 using Tapatalk
Hans@GZP
08-28-2013, 10:04 AM
Don't be surprised if the threads on the O2 sensor bung strip out.
Jimvr4
08-28-2013, 10:30 AM
I had a shop do it after trying with heat, a proper O2 socket and a 24 inch breaker bar. They use an oxy torch and after it gets good and hot, throw water on it to shock it. He got it out and the threads were fine. O2 sensor and threads were fine too.
mb3000
08-28-2013, 03:20 PM
I used an angle grinder to grind the sensor in half so I could fit a regular socket on it. Got it right off with the leverage from my breaker bar.
FluffyCow
08-28-2013, 04:48 PM
I'll heat yhe fuck out of it with my acetylene torch that I have for work. Then I'll take my o2 socket on my electric impact gun and zip it out.
Sent from my SAMSUNG-SGH-I747 using Tapatalk 4
Powered by vBulletin® Version 4.2.3 Copyright © 2025 vBulletin Solutions, Inc. All rights reserved.